    #1 is a terrible idea if you ever need to hire an electrician in the future, plan on selling your house, etc. The National Electric Code prohibits using white, green, or grey wire for a hot/load connection. The 120V cable will contain a black wire for the hot connection, white for neutral, and green for ground. To properly convert it to 240V you would need a cable that consists of black & red wires for the two 120V legs.

    If your home ever suffered an electrical fire then this sort of jury rigging is precisely the sort of thing any competent insurance inspector would spot, and insurance carriers would deny coverage for since it clearly isn’t code compliant, which means a licensed electrician didn’t install it and it wasn’t properly inspected.

    • spongebue@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      7 hours ago

      The “120 volt cable”, assuming you mean NM-B aka Romex, is rated for up to 600 volts if you look at it closely. It is absolutely acceptable to use that wiring for a 240V circuit, as long as you wrap colored (not green) electrical tape around the white neutral wire to indicate it’s another hot.

      Yes, there are 3-conductor (plus ground) wires one can also use for switches and 240V circuits with neutral. That neutral can be used to have 120V and 240V together (your oven may use 240V coils, but the light bulb probably runs on 120). Doesn’t mean you need to have it, if your 240V circuit doesn’t need a neutral. My air compressor is just a motor that can run at 240, no neutral needed, and its outlet is wired up with the same kind of Romex used for a 120 right next to it (with black tape to indicate a second hot)

    • partial_accumen@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      ·
      edit-2
      13 hours ago

      #1 is a terrible idea if you ever need to hire an electrician in the future, plan on selling your house, etc. The National Electric Code prohibits using white, green, or grey wire for a hot/load connection. The 120V cable will contain a black wire for the hot connection, white for neutral, and green for ground. To properly convert it to 240V you would need a cable that consists of black & red wires for the two 120V legs.

      I’ll be the first to admit I’m no certified Sparky, but wire relabeling is used in a number of situations fully in accordance with NEC. My understanding is that some of this is in NEC 200.7. It requires relabeling both ends, but I don’t think there’s any code violation with it. If what you’re saying was true, wouldn’t that mean any -2 NM (Romex) would be code incompatible with 240v loads? I don’t think that’s true.

      Edit: here’s a Sparky doing exactly that